ECP400/750/1000 VD
Brochure download

A LINE OF POWER BOARDS FOR REFRIGERATION SYSTEMS

A line of power boards for refrigeration systems with three-phase compressors up to 10 HP to be linked to a thermostat, thermo-regulator or out-of-room control unit. An electromechanical timer is incorporated for timed defrosts.

Applications
Control of three-phase static or ventilated refrigeration units up to 10 HP, with electric or off-cycle defrost linked to a thermostat, thermo-regulator or out-of-room control unit that issues a cold request.

Main characteristics
Direct control of compressor, condenser fans, compressor oil element, defrost elements, evaporator fans, solenoid valve and all standard-compliant electrical safeguards.
Compact unit with self-extinguishing ABS housing panel and IP65 protection rating plus circuit breaker on front of panel.
Electromechanical timer for timed defrosts.
System status indicated by LED icon.
Can be controlled by thermostat, thermo-regulator or out-of-room control unit.
Can house thermo-regulator on front of panel.

Options
Installation of magnetothermic circuit breakers instead of fuses.
Compressor shutdown in pump-down mode.


 

TECHNICAL CHARACTERISTICS
ECP400 VD
ECP750 VD
ECP1000 VD
Box dimension
350x450x160 mm 350x450x160 mm 350x450x160 mm
Weight 6 Kg 6 Kg 7 Kg
Protection rating
IP 65 IP 65 IP 65
Power supply (3F+N+T)
400 V AC ±10%
50/60 Hz
400 V AC ±10%
50/60 Hz
400 V AC ±10%
50/60 Hz
Load type
Three-phase Three-phase Three-phase
Working temperature
-5 ÷ +50°C -5 ÷ +50°C -5 ÷ +50°C
Storage temperature -10 ÷ +70°C -10 ÷ +70°C -10 ÷ +70°C
Relative ambient humidity
< 90% Rh
< 90% Rh < 90% Rh
Main switch
32 A 32 A 32 A
Overload protection
Thermal relay
Thermal relay Thermal relay
General protection Fuses Fuses Fuses
Control
External ON/OFF external
thermoregulator - remote control panel
External ON/OFF external
thermoregulator - remote control panel
External ON/OFF external
thermoregulator - remote control panel
Defrosting

Electrical

Electrical Electrical
Insulation transformer
PRESENT PRESENT PRESENT
Status indicators
Led Led Led
Alarm signals
Led Led Led
INPUTS
Thermostat or pressure switch
PRESENT PRESENT PRESENT
Oil differential pressure switch


PRESENT
Hig/low pressure switch
PRESENT PRESENT PRESENT
KRIWAN®connection PRESENT PRESENT PRESENT
Condenser fans regulator press. switch (r.p.s)
PRESENT PRESENT PRESENT
OUTPUTS
Compressor
2200 ÷ 3000 W
(3÷4 HP)
3000 ÷ 5500 W
(4÷7,5 HP)
5500 ÷ 7500 W
(7÷10 HP)
Condenser fans output 1

800 W--------(1 PH)

800 W-------(1 PH)

2000 W
(1 PH / 3 PH)
Condenser fans output 2 (separated)
total--------- (1 PH) totali -------- (1 PH) 2000 W
(1 PH / 3 PH)
Evaporator fans
2000 W (1 PH) 2000 W (1 PH) 2000 W
(1 PH / 3 PH)
Defrosting heaters
7500 W (AC1) 9000 W (AC1) 12000 W (AC1)
Room light
PRESENT PRESENT PRESENT
Solenoid valve
PRESENT PRESENT PRESENT
Compressor oil heater
PRESENT PRESENT PRESENT
DIMENSION
ECP400-VD ECP750-VD ECP1000-VD
CONNECTION SCHEME
ECP400-VD ECP750-VD ECP1000-VD