ECP300 EXPERT VD
Brochure download

A LINE OF POWER AND CONTROL PANELS FOR REFRIGERATION SYSTEMS

A line of power and control panels for refrigeration systems with three-phase compressor up to 7,5 HP, for the complete management of cold room. Magnetothermic protection and motor circuit breaker for the compressor accessible from the front panel linked to an innovative form makes it a perfect and functional choice.

Available version with PULSE electronic valve integrated control.

Applications
Control of three-phase refrigeration plant up  to 7.5 HP, static or ventilated, with off-cycle or  electrical defrosting.

Options
Hot-gas defrost control.

Main characteristics
Direct control of the compressor, condenser  fans, compressor oil heater, defrosting heaters, evaporator fans, solenoid valve, room light and all standard-compliant electrical safeguards.
General magnetothermic circuit breaker accessible from the front panel, which cuts the  general power supply.
Adjustable motor circuit breaker for compressor protection accessible from the front panel.
Easy wiring on the internal terminal block.
Selection of functioning mode for the compressor (pump-down / thermostat).
Auxiliary relay with activation configurable by parameter.
Transparent cover for access to magnetothermic circuit breaker, all with IP 65 protection rating.
Electronic control with wide LED display and easy to use buttons.
Signaling with LED icons of the plant status.
RS485 for connection to TeleNET industrial supervision network or modbus-RTU standard protocol.

 

TECHNICAL CHARACTERISTICS
ECP 300 EXPERT VD 4
ECP 300 EXPERT VD 7
Box dimension
400 x 300 x 135 mm
400 x 300 x 135 mm
Weight
9 Kg
10 Kg
Protection rating
IP 65
IP 65
Power supply (3F + N + T)
400 V AC ±10% 50/60 Hz
400 V AC ±10% 50/60 Hz
Load type
Three-phase Three-phase
Working temperature
-5 ÷ +40°C
-5 ÷ +40°C
Storage temperature -25 ÷ +55°C -25 ÷ +55°C
Relative ambient humidity
30% - 90% Rh
without condensate
30% - 90% Rh
without condensate
Range of reading
-45 ÷ +45°C -45 ÷ +45°C
Main switch - general protection
4 poles magnetothermic 16A
4 poles magnetothermic 25A
Compressor protection
Motor circuit breaker
Motor circuit breaker
Control
PEGO PEGO
Defrosting
Electrical Electrical
Status indicators
Led + Display
Led + Display
Alarm signals
Led + Buzzer
Led + Buzzer
INPUTS
Ambient probe
NTC 10 KΩ
NTC 10 KΩ
Evaporator probe
NTC 10 KΩ NTC 10 KΩ
Door switch
PRESENT PRESENT
High/low pressure switch
PRESENT PRESENT
KRIWAN® connection
PRESENT PRESENT
Compressor functioning mode selection
Pump Down - Thermostat
Pump Down - Thermostat
OUTPUTS
Compressor
370 W ÷ 3000 W
(0,5 ÷ 4 HP)
3000 W ÷ 5500 W
(4 ÷ 7,5 HP)
Condenser fans output 1
800 W (1PH)
800 W-----(1PH)
total-------(1PH)
Condenser fans output 2 (separated)

Evaporator fans
500 W (1PH) 2000 W (1PH / 3PH)
Defrosting heaters
6000 W (AC1)
Eq. resistive load

9000 W (AC1)
Eq. resistive load
Room light
800 W (AC1) - Resistive load 800 W (AC1) - Resistive load
Solenoid valve
PRESENT PRESENT
Compressor oil heater
PRESENT PRESENT
Alarm relay
PRESENT PRESENT
Supervision system
TELENET / MODBUS-RTU
TELENET / MODBUS-RTU
DIMENSION
ECP300-EXPERT-VD-4 ECP300-EXPERT-VD-7
CONNECTION SCHEME
ECP300-EXPERT-VD-4 ECP300-EXPERT-VD-7

 

DOWNLOAD INSTRUCTION
Instruction manual
(documentation available through registration)