ECP300 EXPERT U VD
Brochure download

A LINE OF POWER AND ELECTRONIC CONTROL PANELS FOR CONTROL OF THE EVAPORATING UNIT ONLY

A line of power and control panels for refrigeration systems to control only the three-phase evaporating unit where units are served by a central refrigerator or remote condenser unit. Magnetothermic and differential protection for room light accessible from the front panel linked to an innovative form makes it a perfect and functional choice.

Available version with PULSE electronic valve integrated control.

Applications
Control of evaporating unit with electrical defrost up to 12 kW.

Main characteristics
Enable for motor condenser unit, defrosting elements, evaporator fans, solenoid valve, room light and all standard-compliant electrical safeguards.
Magnetothermic circuit breaker accessible from the front panel, which cuts the general power supply.
Differential magnetothermic dedicated to room light accessible from the front panel (see the table).
Easy wiring on the internal terminal block.
Auxiliary relay with activation configurable by parameter.
Transparent cover for access to all the protections, all with IP65 protection rating.
Electronic control with wide LED display and easy to use buttons.
Signaling with LED icons of the plant status.
RS485 for connection to TeleNET industrial supervision network or Modbus-RTU standard protocol.

 

TECHNICAL CHARACTERISTICS
ECP300 EXPERT U VD 6
ECP300 EXPERT U VD 12
Box dimension
400 x 300 x 135 mm
400 x 300 x 135 mm
Weight
9 Kg
10 Kg
Protection rating
IP 65
IP 65
Power supply (3F + N + T)
400 V AC ±10% 50/60 Hz
400 V AC ±10% 50/60 Hz
Load type
Three-phase Three-phase
Working temperature
-5 ÷ +40°C
-5 ÷ +40°C
Storage temperature -25 ÷ +55°C -25 ÷ +55°C
Relative ambient humidity
30% - 90% Rh without condensate
30% - 90% Rh without condensate
Range of reading -45 ÷ +45°C -45 ÷ +45°C
Main switch/general protection
4 poles magnetothermic 16A
4 poles magnetothermic 25A
Room light protection
Differential magnetothermic circuit breaker (optional)
Differential magnetothermic circuit breaker
Control
PEGO PEGO
Defrosting
Electrical Electrical
Status indicators
Led + Display
Led + Display
Alarm signals
Led + Buzzer
Led + Buzzer
INPUTS
Ambient probe
NTC 10 KΩ
NTC 10 KΩ
Evaporator probe
NTC 10 KΩ NTC 10 KΩ
Door switch
PRESENT PRESENT
Man in cold-room alarm
AVAILABLE AVAILABLE
OUTPUT
Evaporator fans
550 W (1PH) 2000 W (1PH / 3PH)
Defrosting heaters
6000 W (AC1)
Eq. resistive load

12000 W (AC1)
Eq. resistive load
Room light
800 W (AC1) - Resistive load
1200 W (AC1) - Resistive load
Solenoid valve
PRESENT PRESENT
Enable condensing unit
PRESENT PRESENT
Configurable alarm relay
PRESENT PRESENT
Door heater
PRESENT PRESENT
Supervision system
TELENET / MODBUS-RTU
TELENET / MODBUS-RTU
DIMENSION
ECP300-EXPERT-U-VD-6 ECP300-EXPERT-U-VD-12
CONNECTION SCHEME
ECP300-EXPERT-U-VD-6 ECP300-EXPERT-U-VD-12

 

DOWNLOAD INSTRUCTION
Instruction manual
(documentation available through registration)