Italian - ItalyEnglish (United Kingdom)French (Fr)Español(Spanish Formal International)Deutsch (DE-CH-AT)

.

PRODUCTS
THERMOSTATS
EXPERT NANO SNOW
EXPERT NANO 1LT
EXPERT NANO 3CF
EXPERT NANO 4CK
EXPERT NANO 2ZN
EXPERT NANO MILK
NANO BOX
NANO ADAPTER
MODULAR ELECTRONICS
PEV series
PEV PULSE
PEV STEPPER
PEV P20
PEV S27
NEXUS series
NEXUS P20
NEXUS S27
VISION series
VISION SC 600
VISION THR
VISION 2PLT
200CASVIS03
VISION TOUCH series
VISION TOUCH THR
VISION TOUCH PAN
VISION TOUCH AB
VISION TOUCH WELLNESS
VISION TOUCH
COPL24II
ACCFLTOUCH
400SAUNASENS
PLUS100 series
PLUS100 AB
PLUS100 PAN
PLUS100 THR
PLUS100 2PLT
DIN NANO series
DIN NANO 4CK
DIN NANO 5CK
DIN NANO SC500
DIN CHILLER
DIN NANO FSC
DIN SPM
ELECTRICAL BOARDS
Serie HYPERANGE
HYPERANGE 030 B6 VEH-1 / VEH-2
HYPERANGE 075 / 100 B6 VEH
BASE series
ECP 202 BASE
ECP 300 BASE4 VD
ECP 400/750/1000 BASE4 VD
ECP 1500/2000/2500 BASE4 VDE
ECP 300 BASE4 U VD
ECP 400/750/1000 BASE4 U VD
ECP 7.5/15/19.5 BASE4 U VDE
ECP 25/36 BASE4 U VDE
ECP 16/21 BASE STEPPER U VDE
ECP 30/42 BASE STEPPER U VDE
ECP 1000 2EV U
EXPERT series
ECP 202 EXPERT
ECP 202 EXPERT D7.5
ECP 200 EXPERT 2EV
ECP 200 EXPERT PULSE
ECP 300 EXPERT VD
ECP 300 EXPERT U VD
ECP 300 EXPERT STEPPER U VD
PLUS series
PLUS200 2PLT
PLUS1000 THR
PLUS EXPERT series
PLUSR 200 EXPERT
PLUSR 300 EXPERT VD
PLUSR 300 EXPERT U VD
PLUSR EXPERT DL3
PLUSR EXPERT DL8
PLUS 200 EXPERT THR
PLUS 300 EXPERT U THR
NANO VD > NANO U VD series
NANO 04 VD
NANO 300 VD
NANO 400/750/1000 VD
NANO 7.5 U VD
NANO 15/19,5 U VD
VD > VD CR > APE series
ECP 04 / ECP 04 M
ECP 07/10
ECP 15
ECP 20
ECP 30
ECP 300 VD
ECP 400/750/1000 VD
ECP 300 VD CR
ECP 400/750/1000 VD CR
ECP 1500/2000/2500 VD CR
ECP __ U VDE CR
ECP 1000 2EV U CR
ECP APE 03
SUPERVISION SYSTEM
TELENET WEB
EXPERT GSM
TWM3 T P UR
TWM3 IO
ACCESSORIES
EXPERT GSM
ECP APE 03
MICRO P
CUSTOMIZED PANELS
EXAMPLES
QUOTATION REQUEST
PILOT SYSTEM
HUMIDIFIERS
LIGHTING
EXPERT LED
EXPERT LED LV
EXPERT LED MEAT
EXPERT LED EMERGENCY
APPLICATIONS
COLD ROOMS
HYPERANGE Series
HYPERANGE 030 B6 VEH-1 / VEH-2
HYPERANGE 075 / 100 B6 VEH
ECP 202 EXPERT
ECP 202 EXPERT D7.5
ECP 200 EXPERT 2EV
ECP 200 EXPERT PULSE
ECP 300 EXPERT VD
ECP 202 BASE
ECP 300 BASE4 VD
ECP 400/750/1000 BASE4 VD
ECP 1500/2000/2500 BASE4 VDE
ECP 300 VD
ECP 400/750/1000 VD
ECP 300 VD CR
ECP 400/750/1000 VD CR
ECP 1500/2000/2500 VD CR
NANO 04 VD
NANO 300 VD
NANO 400/750/1000 VD
Micro P
CONDENSING UNITS
ECP 04 / ECP 04 M
ECP 07/10
ECP 15
ECP 20
ECP 30
EVAPORATING UNIT
ECP 300 EXPERT U VD
ECP 300 EXPERT STEPPER U VD
ECP 300 BASE4 U VD
ECP 400/750/1000 BASE4 U VD
ECP 7.5/15/19.5 BASE4 U VDE
ECP 25/36 BASE4 U VDE
ECP 1000 2EV U
NANO 7.5 U VD
NANO 15/19,5 U VD
ECP 16/21 BASE STEPPER U VD
ECP 30/42 BASE STEPPER U VD
DISPLAY WINDOWS AND REFRIGERATION UNITS
EXPERT NANO 1LT
EXPERT NANO 3CF
EXPERT NANO 4CK
NANO ADAPTER
DIN NANO 4CK
DIN NANO 5CK
PEV PULSE
PEV STEPPER
PILOT SYSTEM
PEV P20
PEV S27
NEXUS P20
NEXUS S27
DATALOGGER
PLUSR 200 EXPERT
PLUSR 300 EXPERT VD
PLUSR 300 EXPERT U VD
PLUSR EXPERT DL3
PLUSR EXPERT DL8
SUPERVISION SYSTEM AND ALARMS
TELENET WEB
EXPERT GSM
TWM3 T P UR
TWM3 IO
ECP APE 03
FAN SPEED CONTROLLER
DIN NANO FSC
DIN SPM
COMPRESSOR RACK AND CHILLER
VISION SC 600
DIN NANO SC 500
DIN CHILLER
DOUBLE SAFETY SYSTEM
VISION 2PLT
PLUS100 2PLT
PLUS200 2PLT
SEASONING
PLUS 200 EXPERT THR
PLUS 300 EXPERT U THR
PLUS1000 THR
PLUS100 THR
VISION THR
VISION TOUCH THR
SONEE16F6A21
PAUSE-LEAVENING
PLUS100 PAN
VISION TOUCH PAN
SONEE16F6A21
DEEP FREEZERS
PLUS100 AB
VISION TOUCH AB
WELLNESS
VISION TOUCH WELLNESS
LIGHTING
EXPERT LED
EXPERT LED LV
EXPERT LED MEAT
EXPERT LED EMERGENCY
SPECIAL APPLICATIONS
EXPERT NANO 2ZN
EXPERT NANO MILK
TECHNICAL DOCUMENTATION

......................................................

Follow us:
TeleNET WEB Brochure download

APPLICATION FOR THE MONITORING AND SUPERVISION OF REFRIGERATION SYSTEMS

TeleNET is an application for the monitoring and supervision of refrigeration and conditioning systems controlled by Pego electronic instruments. The network of instruments channels the data onto a personal computer where it is possible to display and print reports, manage alarms, modify operating parameters and monitor the whole system.

 

Installation of the WEB package enables quick, complete and simple access to the network tools via the web browser, also from smartphone and tablet.

TELENET

Applications
Monitoring and supervision of refrigeration and conditioning systems.
Automatic control of work cycles.
Recording of physical parameters (temperature, humidity, pressure, CO2 etc.).
Industrial cooling, storage, seasoning systems.
Registration and consultation of data saved on Secure Digital card (for Pego electrical panel plus Expert series).


Main characteristics
Industrial supervision system for Pego electronic controls with RS485 output.
Allows interaction with instruments.
Suitable for local networks (LAN) in client/server configuration.
Control of work cycles with automatic modification of parameters over time.
Integrated data backup and restore.
Remote system control.
Home page can be configured to show selected instrument data.
Customized graphics with parameters comparison.
Possibility to print the registered data or export them in Excel format.
HACCP table.
Alarms navigator.
A differentiated alarm management and transmission of e-mails to mobile phones and computers to inform user of alarm activation/ deactivation.
User-friendly program updating with download from PEGO website.
No limit to connectable instruments with the addition of TWRS485 interfaces (unique interface available for connection up to 64 instruments).
Compatibility with other manufacturer's instruments (communication via Modbus RTU protocol).
Self-recognition of instruments connected to the Telenet network.
Visualization of instruments on the map (synoptic).


System requisites
Operating system: Windows 7, Windows 8/8.1, Windows 10, Windows Server 2008, Windows Server 2012.
RAM memory 2 GB (recommended 4 GB).
Hard disk 10 GB available space.
Min. resolution 1024x768 24 bit (recommended 1280x1024 32 bit).
N. 1 USB port to 2TWRS485 interface.
2 Ghz processor or higher.

 

Screenshot demonstration of TeleNET monitoring system

 

TECHNICAL CHARACTERISTICS
TeleNET
TWRS485 interface dimension 210 x 200 x 48 mm
TWRS485 interface  weight 0,5 Kg
Number of connectable instruments
Unlimited (subject to verification of available connection line capacity and hardware resources)
Alarm relay
Require TWMA
Sampled variables print-out
PRESENT
Graphics print-out
PRESENT
Event history
PRESENT
Sampling interval
From 1 min.
Data export PRESENT
Manage alarms / send e-mail
PRESENT
Automatic work cycle
PRESENT
Client/Server
PRESENT
User management by password and authorisation levels
PRESENT
DIMENSION
TELENET
CONNECTION SCHEME
TELENET

 

DOWNLOAD INSTRUCTION
Instruction manual