ECP400/750/1000 BASE4 U VD
Brochure download

POWER AND ELECTRONIC CONTROL PANELS TO MANAGE EVAPORATING UNIT ONLY

A line of power and electronic control panels to manage the three-phase evaporating unit only where devices are served by a compressor rack. Various power ranges and a wide range of optionals allow you to choose the panel best suited to your system.

Application
Control of evaporating unit only with electrical defrost up to 12 kw.

Options
Magnetothermic circuit breakers installed instead of fuses.
Free-voltage contact alarm output to activate other warning devices such as sirens or dialers.

Main characteristic
Enabling for condensing unit, defrosting  elements, evaporator fans, solenoid valve,  room light and all standard-compliant electrical  safeguards.
Compact, self-extinguishing ABS housing with  IP65 protection rating and circuit breaker on front  of panel.
Control electronics with large backlit LCD and  user-friendly keypad.
LED system status indicators.
RS485 for connection to TeleNET industrial  supervision network or Modbus-RTU standard  protocol.

 

TECHNICAL CHARACTERISTICS
ECP400
BASE4 U VD
ECP750
BASE4 U VD
ECP1000
BASE4 U VD
Box dimension
350x450x160 mm 350x450x160 mm 350x450x160 mm
Wieght 6 Kg 6 Kg 7 Kg
Protection rating
IP 65 IP 65 IP 65
Power supply
400 V AC ±10%
50/60 Hz
400 V AC ±10%
50/60 Hz
400 V AC ±10%
50/60 Hz
Load type Three-phase Three-phase Three-phase
Working temperature
-5 ÷ +50°C -5 ÷ +50°C -5 ÷ +50°C
Storage temperature -10 ÷ +70°C -10 ÷ +70°C -10 ÷ +70°C
Relative ambient humidity
< 90% Rh
< 90% Rh < 90% Rh
Range of reading -45 ÷ +45°C -45 ÷ +45°C -45 ÷ +45°C
Main switch
32 A 32 A 32 A
General protection Fuses Fuses Fuses
Control
PEGO PEGO PEGO
Defrosting
Electrical Electrical Electrical
Insulation transformer
PRESENT PRESENT PRESENT
Status indicator
Led + Display Led + Display Led + Display
Alarm signals
Led + Buzzer Led + Buzzer Led + Buzzer
INPUTS
Ambient probe NTC 10 KΩ NTC 10 KΩ NTC 10 KΩ
Evaporator probe
NTC 10 KΩ NTC 10 KΩ NTC 10 KΩ
Door switch PRESENT PRESENT PRESENT
Man in cold-room alarm
AVAILABLE AVAILABLE AVAILABLE
OUTPUTS
Evaporator fans 2000 W (1 PH) 2x2000 W (1 PH) 3x2000 W
(1 PH / 3 PH)
Defrosting heater 7500 W 9000 W 12000 W
Room light
PRESENT PRESENT PRESENT
Solenoid valve
PRESENT PRESENT PRESENT
Enable condensing unit
PRESENT PRESENT PRESENT
Alarm relay PRESENT
(on request)
PRESENT
(on request)
PRESENT
(on request)
Supervision system TELENET/ MODBUS-RTU TELENET/ MODBUS-RTU TELENET/ MODBUS-RTU
DIMENSION
ECP400-Base4-U-VD ECP750-Base4-U-VD ECP1000-Base4-U-VD
CONNECTION SCHEME
ECP400-Base4-U-VD ECP750-Base4-U-VD ECP1000-Base4-U-VD

 

 

DOWNLOAD INSTRUCTION
Instruction manual
(documentation available through registration)