PRODUCTS | ELECTRICAL BOARDS
ECP300 VD
A LINE OF POWER BOARDS FOR REFRIGERATION SYSTEMS
A line of power boards for refrigeration systems with three-phase compressors up to 3 HP to be linked to a thermostat, thermo-regulator or out-of-room control unit. An electromechanical timer is incorporated for timed defrosts.
Applications
-
Control of three-phase static or ventilated refrigeration units up to 3 HP, with electric or off-cycle defrost linked to a thermostat, thermo-regulator or out-of-room control unit that issues a cold request.
Main characteristics
- Direct control of compressor, condenser fans, compressor oil element, defrost elements, evaporator fans, solenoid valve and all standard-compliant electrical safeguards.
- Compact unit with self-extinguishing ABS housing panel and IP65 protection rating plus circuit breaker on front of panel.
- Electromechanical timer for timed defrosts.
- System status indicated by LED icon.
- Can be controlled by thermostat, thermo-regulator or out-of-room control unit.
- Can house thermo-regulator on front of panel.
Options
- Installation of magnetothermic circuit breakers instead of fuses.
- Compressor shutdown in pump-down mode.
Properties
Dimension
ECP 300 VD
290x340x145 mm
Weight
ECP 300 VD
5kg
Front protection rating
ECP 300 VD
IP 65
Power supply
ECP 300 VD
400 VAC ±10% 50/60 Hz
Status indicator
ECP 300 VD
Led
Load type
ECP 300 VD
Three phase
Working temperature
ECP 300 VD
-5 ÷ +50 °C
Storage temperature
ECP 300 VD
-10 ÷ +70°C
Relative ambient humidity
ECP 300 VD
30% - 90% RH without condensate
Door lock main switch
ECP 300 VD
16 A
Compressor protection
ECP 300 VD
Thermal relay
General protection
ECP 300 VD
Fuses
Control
ECP 300 VD
External ON/OFF external thermoregulator - remote control panel
Alarm signals
ECP 300 VD
Led
Defrosting
ECP 300 VD
Electrical
High/low pressure switch
ECP 300 VD
Present
Thermostat or pressure switch
ECP 300 VD
Present
Thermostat or pressure switch
ECP 300 VD
Present
Kriwan® connection
ECP 300 VD
Present
Compressor
ECP 300 VD
2200W (0,5÷3 HP)
Defrosting heaters 1
ECP 300 VD
4000W (AC1)
Evaporator fans 1
ECP 300 VD
800W (1PH)
Condenser fans output 1
ECP 300 VD
800W (1PH)
Solenoid valve 1
ECP 300 VD
Present
Technical Characteristics
Inputs
Outputs
Dimensions and Diagram
Available Versions
ECP 300 VD
Product Code
102300VD01
102300VD02
102300VD03
102300VD04
102300VD05
Compressor
Product Code
102300VD01
102300VD01
1.6 - 2.5 A
Product Code
102300VD02
102300VD02
2.5 - 4.0 A
Product Code
102300VD03
102300VD03
4.0 - 6.0 A
Product Code
102300VD04
102300VD04
5.5 - 8.0 A
Product Code
102300VD05
102300VD05
7.0 - 10.0 A
Evaporator fan
Product Code
102300VD01
102300VD01
0,8 kW
Product Code
102300VD02
102300VD02
0,8 kW
Product Code
102300VD03
102300VD03
0,8 kW
Product Code
102300VD04
102300VD04
0,8 kW
Product Code
102300VD05
102300VD05
0,8 kW
Defrosting
Product Code
102300VD01
102300VD01
4,0 kW
Product Code
102300VD02
102300VD02
4,0 kW
Product Code
102300VD03
102300VD03
4,0 kW
Product Code
102300VD04
102300VD04
4,0 kW
Product Code
102300VD05
102300VD05
4,0 kW
Electronic expansion valve
Product Code
102300VD01
102300VD01
No
Product Code
102300VD02
102300VD02
No
Product Code
102300VD03
102300VD03
No
Product Code
102300VD04
102300VD04
No
Product Code
102300VD05
102300VD05
No
Man in cold-room alarm
Product Code
102300VD01
102300VD01
No
Product Code
102300VD02
102300VD02
No
Product Code
102300VD03
102300VD03
No
Product Code
102300VD04
102300VD04
No
Product Code
102300VD05
102300VD05
No
Complete cold room management
Product Code
102300VD01
102300VD01
Yes
Product Code
102300VD02
102300VD02
Yes
Product Code
102300VD03
102300VD03
Yes
Product Code
102300VD04
102300VD04
Yes
Product Code
102300VD05
102300VD05
Yes
Condensing unit management
Product Code
102300VD01
102300VD01
No
Product Code
102300VD02
102300VD02
No
Product Code
102300VD03
102300VD03
No
Product Code
102300VD04
102300VD04
No
Product Code
102300VD05
102300VD05
No
Temperature/Humidity Management
Product Code
102300VD01
102300VD01
No
Product Code
102300VD02
102300VD02
No
Product Code
102300VD03
102300VD03
No
Product Code
102300VD04
102300VD04
No
Product Code
102300VD05
102300VD05
No
Evaporating unit management
Product Code
102300VD01
102300VD01
No
Product Code
102300VD02
102300VD02
No
Product Code
102300VD03
102300VD03
No
Product Code
102300VD04
102300VD04
No
Product Code
102300VD05
102300VD05
No
Double system management
Product Code
102300VD01
102300VD01
No
Product Code
102300VD02
102300VD02
No
Product Code
102300VD03
102300VD03
No
Product Code
102300VD04
102300VD04
No
Product Code
102300VD05
102300VD05
No
Valve management electronic on/off
Product Code
102300VD01
102300VD01
No
Product Code
102300VD02
102300VD02
No
Product Code
102300VD03
102300VD03
No
Product Code
102300VD04
102300VD04
No
Product Code
102300VD05
102300VD05
No
Valve management Stepper electronics
Product Code
102300VD01
102300VD01
No
Product Code
102300VD02
102300VD02
No
Product Code
102300VD03
102300VD03
No
Product Code
102300VD04
102300VD04
No
Product Code
102300VD05
102300VD05
No
Double evaporator management
Product Code
102300VD01
102300VD01
No
Product Code
102300VD02
102300VD02
No
Product Code
102300VD03
102300VD03
No
Product Code
102300VD04
102300VD04
No
Product Code
102300VD05
102300VD05
No
Datalogger
Product Code
102300VD01
102300VD01
No
Product Code
102300VD02
102300VD02
No
Product Code
102300VD03
102300VD03
No
Product Code
102300VD04
102300VD04
No
Product Code
102300VD05
102300VD05
No
Manuals