Skip to main content
PRODUCTS | ELECTRICAL BOARDS
ECP300 BASE4 VD

A LINE OF CONTROL PANELS FOR COLD ROOMS.

A LINE OF CONTROL PANELS FOR COLD ROOMS.
A LINE OF CONTROL PANELS FOR COLD ROOMS.

    A line of control panels for cold rooms with three-phase compressor up to 3 HP, specially designed for complete cold room management. Together with the various options, the different power ranges allow the user to select a unit that is “custom- made” to suit the refrigeration system.

    A LINE OF CONTROL PANELS FOR COLD ROOMS.
    A LINE OF CONTROL PANELS FOR COLD ROOMS.
      Applications
      • Complete control of three-phase static or ventilated refrigeration systems up to 3 HP, off-cycle or electrical defrosting.

      Options
      • Installation of magnetothermic protection devices instead of fuses.
      • Alarm output with free-voltage contact to activate further warning devices such as siren or dialer.
      • Pump-down compressor stop.
      • Hot-gas defrost control.
      Main characteristic
      • Direct control of compressor, condenser fans, compressor oil heater, defrosting heaters, evaporator fans, solenoid valve, room light and all standard-compliant electrical protection devices.
      • Compact, self-extinguishing ABS housing with IP65 protection rating and frontal circuit-breaker.
      • Electronic control with wide LED display and user-friendly keypad.
      • System status indicated by icons.
      • RS485 for connection to TeleNET industrial supervision network or Modbus-RTU standard protocol.
      Properties
      Dimension
      ECP300 BASE4 VD
      290x340x145 mm
      Weight
      ECP300 BASE4 VD
      5kg
      Front protection rating
      ECP300 BASE4 VD
      IP 65
      Power supply
      ECP300 BASE4 VD
      400 VAC ±10% 50/60 Hz
      Status indicator
      ECP300 BASE4 VD
      Led + Display
      Load type
      ECP300 BASE4 VD
      Three phase
      Working temperature
      ECP300 BASE4 VD
      -5 ÷ +50 °C
      Storage temperature
      ECP300 BASE4 VD
      -10 ÷ +70 °C
      Relative ambient humidity
      ECP300 BASE4 VD
      30% - 90% RH without condensate
      Reading range
      ECP300 BASE4 VD
      -45 ÷ +99°C
      Door lock main switch
      ECP300 BASE4 VD
      16 A
      Compressor protection
      ECP300 BASE4 VD
      Thermal relay
      General protection
      ECP300 BASE4 VD
      Fuses (option: magnetothermic protection)
      Control
      ECP300 BASE4 VD
      Pego
      Alarm signals
      ECP300 BASE4 VD
      Led + Buzzer
      Defrosting
      ECP300 BASE4 VD
      Electrical
      Ambient probe
      ECP300 BASE4 VD
      NTC 10 kΩ
      Evaporator probe 1
      ECP300 BASE4 VD
      NTC 10 kΩ
      Door switch
      ECP300 BASE4 VD
      Present
      High/low pressure switch
      ECP300 BASE4 VD
      Present
      Kriwan® connection
      ECP300 BASE4 VD
      Present
      Compressor
      ECP300 BASE4 VD
      2200W (0,5÷3 HP)
      Defrosting heaters 1
      ECP300 BASE4 VD
      4000W (AC1)
      Evaporator fans 1
      ECP300 BASE4 VD
      800W (1 PH)
      Condenser fans output 1
      ECP300 BASE4 VD
      800W (1 PH)
      Solenoid valve 1
      ECP300 BASE4 VD
      Present
      Compressor oil heater
      ECP300 BASE4 VD
      Present
      Room light
      ECP300 BASE4 VD
      Present
      2 Configurable relays
      ECP300 BASE4 VD
      Present
      Supervision
      ECP300 BASE4 VD
      TeleNet / Modbus-RTU
      Dimension
      ECP300 BASE4 VD
      ECP300 BASE4 VD
      Connection Scheme
      ECP300 BASE4 VD
      ECP300 BASE4 VD
      Technical Characteristics
      Inputs
      Outputs
      Dimensions and Diagram
      Manuals
      Info
      IT
      EN
      FR
      ES
      DE
      Modbus