A LINE OF CONTROL PANELS FOR COLD ROOMS

A line of control panels for cold rooms with single-phase compressor up to 2 HP, specially designed to provide greater flexibility at a competitive cost.

Main characteristics
Direct control of compressor, defrosting heaters, evaporator fans and room light using free-voltage contacts.
Compact, self-extinguishing ABS housing with IP65 protection rating.
On “A” versions there is an auxiliary relay with parameter-configurable activation (alarm, temperature set-point, direct frontal pushbutton control, door heater elements, freon solenoid control where pump-down compressor operation is applied).
RS485 for connection to TeleNET industrial supervision network or Modbus-RTU standard protocol.

ECP 200 Base2
Allows user to control compressor and cold room light. Configurable auxiliary relay or alarm output also available on the ECP200 Base 2A version.
Applications
Single-phase system up to 2 HP, off-cycle defrosting.
Remote control for compressor enabling to be linked to power board.

ECP 200 Base4
Allows user to control all the components on the refrigeration system: compressor, evaporator fans, defrosting heaters and room light. Configurable auxiliary relay or alarm output also available on the ECP200 Base 4A version.
Applications
Single-phase static or ventilated system up to 2 HP , off-cycle or electrical defrosting with direct compressor shutdown (or in pump-down mode, on the ECP 200 BASE4 A version).
Remote control for compressor, defrosting and fans enabling to be linked to power board.
Device of single-phase evaporating unit with cold solenoid valve or remote motor condenser unit enabling.

 

TECHNICAL CHARACTERISTICS
ECP200 BASE2
ECP200 BASE4
Dimension 203x193x79 mm
203x193x79 mm
Weight 0,5 Kg 0,5 Kg
Protection rating
IP 65
IP 65
Power supply
230 V AC ±10% 50/60 Hz
230 V AC ±10% 50/60 Hz
Load type
Single-phase
Single-phase
Working temperature
-5 ÷ +50°C
-5 ÷ +50°C
Storage temperature -10 ÷ +70°C -10 ÷ +70°C
Relative ambient humidity
< 90% Rh
< 90% Rh
Range of reading -45 ÷ +45°C -45 ÷ +45°C
Defrost Off cycle
Electrical
Status indicators
Led + Display Led + Display
Alarm signals
Led + Buzzer Led + Buzzer
INPUTS
Ambient probe
NTC 10 KΩ
NTC 10 KΩ
Evaporator probe

NTC 10 KΩ
Overload protection
PRESENT
PRESENT
Door switch
PRESENT PRESENT
OUTPUTS
Compressor
1500 W (2 HP)
1500 W (2 HP)
Defrost 3000 W (AC1)
Evaporator fans

500 W
Cold room light
800 W (AC1) 800 W (AC1)
Alarm relay / AUX
(voltage free contact)
PRESENT
(on "A" version only)
PRESENT
(on "A" version only)
Supervision TELENET / MODBUS-RTU
TELENET / MODBUS-RTU
DIMENSION
ECP200-Base2-(A) ECP200-Base4-(A)
CONNECTION SCHEME
ECP200-Base2-(A) ECP200-Base4-(A)